Danfoss 130B6066 Driver Board with IGBT – FC102/202/302 – Tested

130B6066 Driver Board
Add to Inquiry

Description


What Is the Danfoss 130B6066 Driver Board with IGBT Module?

The Danfoss 130B6066 Driver Board with IGBT Module is an inverter power driver assembly listed for selected Danfoss VLT frequency converter applications.

The assembly combines a driver board with an IGBT power module. It is used in the drive’s inverter power section, where the power switching components are controlled to support motor operation.

This listing covers selected FC102, FC202, FC302, and CDS303 applications in the 11–18.5 kW range. The exact board version and IGBT configuration must be checked against the original assembly before ordering.

Key Specifications

Item Details
Brand Danfoss
Part Number 130B6066
Product Type Driver Board with IGBT Module
Listed Drive Series FC102 / FC202 / FC302 / CDS303
Listed Power Range 11–18.5 kW
Application Inverter Power / Driver Section
Assembly Driver Board with IGBT Module
Condition Tested
Compatibility Drive model, power rating, and hardware version dependent

Danfoss 130B6066 driver board with IGBT module

Applications and Compatibility

This assembly is listed for selected Danfoss drive applications:

  • FC102 – VLT HVAC Drive
  • FC202 – VLT AQUA Drive
  • FC302 – VLT AutomationDrive
  • CDS303 – VLT Compressor Drive

The listed power range is 11–18.5 kW. However, different drive models, voltage classes, and power ratings may use different inverter assemblies.

Compatibility must be checked using:

  • Original part number and board identification
  • Drive model and complete type code
  • Drive power rating
  • Supply voltage and frame configuration
  • IGBT module markings and configuration
  • Driver board revision and connector layout

Do not select this assembly based only on the drive series or power rating.

How to Identify the Correct Replacement Driver Board

Before ordering the Danfoss 130B6066 Driver Board with IGBT Module, check the following:

  • Read the part number on the original driver board.
  • Check the identification markings on the IGBT module.
  • Record the complete drive model and type code.
  • Confirm the drive power rating and input voltage.
  • Compare the board revision, connectors, and physical layout.
  • Check whether the original assembly includes the same IGBT module configuration.

Please provide clear photos of both the driver board and IGBT module for comparison.

When Should the Driver Board with IGBT Module Be Replaced?

The driver board or IGBT assembly may require inspection when the frequency converter shows inverter-related faults, output-stage problems, abnormal motor operation, or visible damage to power components.

However, an inverter fault does not automatically mean that the driver board or IGBT module is defective. The power supply, DC bus, motor wiring, gate-drive circuit, and other inverter components should also be checked by a qualified technician.

Danfoss 130B6066 driver board and IGBT module detail

Condition and Testing

This Danfoss 130B6066 Driver Board with IGBT Module is supplied in tested condition.

The assembly is inspected and tested before dispatch. Please contact us if you require details about the test scope or the condition of the available unit.

Tested condition does not guarantee compatibility with every FC102, FC202, FC302, or CDS303 configuration. Confirm the original assembly number, IGBT module markings, and drive specifications before ordering.

Frequently Asked Questions

Q1: Which Danfoss drive series is this assembly listed for?

This listing covers selected FC102, FC202, FC302, and CDS303 applications. Exact compatibility depends on the original assembly and drive configuration.

Q2: What is the listed power range?

The advertised range is 11–18.5 kW. The exact replacement must still match the drive’s power rating and voltage configuration.

Q3: Does this product include the IGBT module?

Yes. This listing describes a driver board supplied with an IGBT module. Please confirm the actual assembly contents and module markings before ordering.

Q4: Is the 130B6066 suitable for every FC102, FC202, and FC302 drive?

No universal compatibility should be assumed. Different drive ratings and hardware configurations may require different assemblies.

Q5: Can this assembly be used in a CDS303 drive?

CDS303 is included in this product listing. Confirm the complete drive type code, power rating, and original assembly number before purchasing.

Q6: Is the driver board with IGBT module tested before shipping?

Yes. This listing is for a tested assembly. Contact us if you need details about the available unit’s test scope.

Q7: What information should I provide to confirm compatibility?

Please provide the original board number, IGBT module markings, drive nameplate, complete type code, and drive power rating.

Need Help Confirming Compatibility?

Not sure whether Danfoss 130B6066 is the correct replacement for your drive?

Send us:

  • A photo of the original driver board
  • A close-up photo of the IGBT module markings
  • The original assembly part number
  • A photo of the drive nameplate
  • The complete drive type code
  • The drive power rating and voltage

We can help compare the available information before you place your order.

Contact sales

E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069

Our products

We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.

Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.

Please contact us and we will serve you as soon as possible.

Send your message to us


Successfully added!