Danfoss 130B6054 Current Detection Board – FC102/202/302 37-45KW – Tested

产品编号:130B6054 Current Detection Board
Add to Inquiry

Description


What Is the 130B6054?

The Danfoss 130B6054 is a current transformer board used in selected VLT frequency converter configurations.

It is an internal electronic component designed for current measurement and feedback within the drive’s power system.

This board is listed for selected FC302 drive applications, including 37kW and 45kW configurations. Some supplier listings also include 55kW applications.

It is offered as tested stock for industrial VFD maintenance, repair and replacement applications.

Before ordering, verify the original board number, voltage designation and drive frame size to ensure correct replacement compatibility.

Key Specifications

Specification Details
Part Number 130B6054
Brand Danfoss
Product Type Current Transformer / Current Detection Board
Drive Series VLT FC Series
Main Listed Application Selected FC302 configurations
Application Power Range 37kW / 45kW
Additional Power Reference 55kW (verify separately)
Voltage Designation 500V
Frame References C1 / C3 / H7 / I7
Condition Tested Stock
Testing Status Tested; confirm available test details before ordering
Application Industrial VFD Current Measurement and Feedback

Danfoss 130B6054 Current Transformer Board

Applications and Compatibility

The Danfoss 130B6054 is identified as a current transformer board for selected VLT frequency converter applications.

Available supplier references associate this board with:

  • FC302 – selected 37kW configurations.
  • FC302 – selected 45kW configurations.
  • FC302 – selected 55kW configurations (additional reference).

The 500V designation and frame references C1, C3, H7 and I7 also appear in industrial spare parts catalogues.

Important Compatibility Checks:

Before ordering, verify:

  • Confirm that the original board carries the exact part number 130B6054.
  • Check the complete Danfoss FC302 drive model code.
  • Verify the drive voltage and power rating.
  • Confirm the frame size: C1, C3, H7 or I7, as applicable.
  • Compare the original board revision and identification markings.
  • Check connector positions and pin configuration.
  • Verify the current transformer board reference against the original equipment documentation.

Do not assume that every FC102, FC202 or FC302 drive rated 37–45kW uses the same current transformer board.

FC102 and FC202 compatibility should be confirmed individually against the complete drive model and original spare parts reference.

How to Identify the Correct Replacement Board

When replacing a current transformer board, carefully compare the existing board with the replacement unit.

Check the following details:

  • Part number printed on the original PCB.
  • Board identification code and revision.
  • Current transformer components and layout.
  • Connector positions and pin configuration.
  • Frame size and mounting arrangement.
  • Complete drive model and nameplate information.

If you are unsure about compatibility, send us clear photos of the existing board and drive nameplate before ordering.

When Should the Current Transformer Board Be Replaced?

A current transformer board may require inspection when the inverter reports abnormal current readings or experiences related current measurement faults.

Before replacing the board:

  • Inspect the board for visible damage or burnt components.
  • Check the current transformer connections.
  • Inspect connectors and wiring.
  • Check the relevant current measurement circuits.
  • Review the drive fault history and diagnostic results.
  • Verify that the replacement part number matches the original board.

Abnormal current readings do not automatically mean the current transformer board is defective. Other sensing components, wiring and power circuit connections should also be inspected by qualified personnel.

Condition and Testing

This product is offered as tested stock for Danfoss VLT frequency converter maintenance and replacement.

Please contact us for available inspection and testing details, actual product photos and current stock availability.

Confirm the physical condition and testing scope before purchase.

Danfoss 130B6054 current transformer board identification label and connector details

Frequently Asked Questions

What is the Danfoss 130B6054 used for?

The 130B6054 is a current transformer / current detection board used in selected Danfoss VLT frequency converter applications.

Is 130B6054 compatible with FC302 37kW and 45kW drives?

Third-party listings associate this board with selected FC302 37kW and 45kW configurations. Confirm the complete drive model and frame size before ordering.

Is 130B6054 compatible with FC102 and FC202?

Compatibility with specific FC102 and FC202 models requires verification. Check the original board number and Danfoss spare parts documentation for your exact drive.

What does the 500V designation mean?

The 500V designation appears in supplier catalogue descriptions for the 130B6054 current transformer card. Confirm the electrical configuration against the original board and drive documentation.

Is this board tested?

This listing is for tested stock. Please request available inspection and functional testing details before purchase.

Need Help Confirming Compatibility?

Looking for a replacement Danfoss 130B6054 current transformer board?

Send us:

  • A clear photo of the existing board.
  • A close-up photo of the 130B6054 identification label.
  • The complete FC102 / FC202 / FC302 drive nameplate.
  • The drive model code and frame size.
  • Your required quantity.

Contact us for product identification, compatibility assistance and quotation.

Contact sales

E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069

Our products

We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.

Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.

Please contact us and we will serve you as soon as possible.

Send your message to us


Successfully added!