Schneider VX4B600100 Control Block – ATV600 All Ratings

产品编号: VX4B600100 Control Block
Add to Inquiry

Description


What Is the VX4B600100?

The Schneider VX4B600100 is the main control block (CPU board) for the Altivar Process ATV600 platform, covering ATV630, ATV650, ATV660, ATV680, ATV6A0, ATV6B0, and ATV6L0 across all power ratings. It handles drive processing, parameter storage, I/O routing, and communication. It is not a power board or a terminal cassette.

Supplied as New / Tested — confirm the exact condition per listing before ordering.

Key Specifications

Specification Value
Part Number VX4B600100
Product Type Control Block (CPU / Main Board)
Compatible Platform ATV630 / 650 / 660 / 680 / 6A0 / 6B0 / 6L0
Power Coverage All power ratings(ATV600 series)
Supply Voltage Range 200 V – 690 V
Integrated Ports Ethernet / Modbus TCP
Condition New / Tested(confirm per unit)

Schneider VX4B600100 control block CPU board for ATV630 ATV650 ATV660 ATV680 drives

When This Control Block Is the Suspect

  • InF0 / InF1 / InF2 / InF3 — relate to internal microprocessor communication interruption or power board rating / software incompatibility with the control block. Check ribbon seating and power-board model before replacing.
  • InF6(Internal Error 6) — the drive fails to recognize an option module. Reseat the removable terminal cassette and any option card before concluding the control block is faulty.
  • InFr(Internal Error 27) — CPLD signal acquisition anomaly on the control card, often linked to poor ribbon connection between the control block and power board after vibration. Reseat the ribbon and verify grounding/shielding.
  • No display / fails to initialize — power is present, but the control block does not boot. Confirm the control-side supply rails before replacing the block.

Compatibility Check

  • Drive series — confirm the drive is ATV630 / 650 / 660 / 680 / 6A0 / 6B0 / 6L0. This block is not for ATV610 or ATV900.
  • Original block marking — confirm the existing control block reads VX4B600100.
  • Fault context — confirm the active fault is an InF-series internal error or a CPU-level symptom. If the fault is terminal-level (e.g., NST, SPF), the relevant part is the I/O cassette, not this control block.
  • If unsure, send a photo of the original control block label and the drive nameplate before purchase.

VX4B600100 control block ribbon connector and interface detail

FAQ

Does InF0 or InFr always mean the VX4B600100 is faulty?

No. InF0 can indicate microprocessor communication interruption or invalid power-board rating. InFr often traces to ribbon seating or interference. Reseat connections and verify grounding before replacing the block.

Is VX4B600100 compatible with ATV610 or ATV900?

No. It is the ATV600 series control block. ATV610 uses a different control architecture, and ATV900 uses VX4B900100.

What does “All power ratings” mean for this block?

Schneider designates VX4B600100 as the control block for the entire ATV600 power range. However, InF2/InF3 faults involve power-board rating and software compatibility, so the power stage configuration must match the control block’s stored data.

Contact sales

E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069

Our products

We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.

Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.

Please contact us and we will serve you as soon as possible.

Send your message to us


Successfully added!