EAV42257-00 IGBT/Power Module Board
The Schneider EAV42257-00 is the inverter power board (Bottom Drive Power Board) used in Altivar ATV610, ATV630, and ATV930 drives in the 30–45 kW range. It carries the IGBT power modules that convert the DC bus voltage into the variable-frequency AC output feeding the motor. In the ATV600/900 power architecture, this board sits at the final power-conversion stage — downstream of the DC bus and upstream of the motor terminals.
This is a power-stage component, not a Control Unit or I/O board. Supplied as New Original stock, it is intended for cases where the original power board has been confirmed faulty, or where IGBT short-circuit / output-stage failure has been isolated after external causes have been excluded.
| Specification | Details |
|---|---|
| Part Number | EAV42257-00 |
| Product Type | IGBT Power Module Board / Inverter Power Board |
| Compatible Drives | ATV610 / ATV630 / ATV930 |
| Power Range | 30–45 kW(部分渠道标注 37–45 kW,以驱动铭牌 MLFB 为准) |
| Board Function | DC-to-AC inversion via on-board IGBT modules |
| Board Group | Group “4” board(按备件渠道标注) |
| Terminations | 10 wires / 2 SCR channels(按 DC Bus Board 归类时) |
| Associated Fault Codes | SCF4(IGBT short circuit);OCF(overcurrent);InF(internal fault)— diagnostic reference only |
| Condition | New Original |
Important Diagnostic Boundary: SCF4 is defined by Schneider as “IGBT short circuit,” but the probable cause can be power-component detection error, not necessarily a physically failed IGBT module. In field cases, SCF1/SCF4 combined with InF/INFR has been traced to an I/O board connector that was partially unseated during reassembly. OCF and InF can also originate from motor cable insulation failure, incorrect motor parameters, or a damaged gate-drive path — all of which must be excluded before the power board is replaced.

The board becomes a legitimate suspect under these conditions, after external causes have been excluded:
Caution: Before ordering, confirm that the motor cable insulation has been tested, the I/O board and ribbon connectors are fully seated, and the motor parameters match the nameplate. These checks resolve a significant share of SCF/OCF/InF trips without replacing the power board.
Before ordering, confirm the following:

It is a power board (IGBT power module board). It handles DC-to-AC power conversion, not drive control logic or I/O signal interfacing.
No. SCF4 indicates IGBT short circuit detection, but Schneider lists power-component detection error as a probable cause. An unseated I/O board connector has also produced combined SCF/InF faults in field cases. Confirm connectors and motor cables before replacing the board.
EAV42257_01 appears as a related number in spare-parts listings, but equivalence should be verified against the drive MLFB and the original board label before ordering. Do not assume a direct drop-in replacement without confirmation.
Contact sales
E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069
Our products
We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.
Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.
Please contact us and we will serve you as soon as possible.