PN072146P1 Surge Absorption
The Schneider PN072146P1 is the input-side surge absorption and filter board used in Altivar ATV61 and ATV71 drives in the 90–132 kW power range. It carries the spare-part designation VX4A1110. In the ATV61/71 power path, this board sits on the input rectification side, suppressing high-frequency transient voltages and conducted noise that could otherwise stress the DC bus and the rectifier components. Its function is protective and filtering-oriented, not switching or triggering.
Supplied as a tested replacement unit, it is intended for cases where the surge absorption path has been isolated as the source of recurrent overvoltage behaviour, after external supply and application-side causes have been excluded.
| Specification | Details |
|---|---|
| Part Number | PN072146P1 |
| Spare-Part Designation | VX4A1110 |
| Product Type | Surge Absorption / Filter Board (input side) |
| Compatible Drives | Altivar ATV61 / ATV71 |
| Power Range | 90 kW – 132 kW |
| Function | Input-side transient voltage suppression and high-frequency filtering |
| Associated Drive Fault | OSF — Mains overvoltage fault(诊断参考) |
| Condition | Tested replacement unit |
Important Functional Boundary: This board performs surge absorption and filtering, not SCR triggering or pre-charging. The ATV61/71 pre-charge and rectifier trigger function is handled by a different board (e.g., PN072139P904 / VX5A1300). If the drive is reporting CrF (pre-charge fault) rather than OSF, the PN072146P1 is not the correct replacement target.

The board becomes a legitimate suspect under the following conditions, after external causes have been excluded:
Caution: OSF can also be caused by mains voltage fluctuation or a faulty internal detection element even when the surge board is functional. The board should be replaced only after the supply-side checks prescribed by Schneider have been completed.
Before ordering, confirm the following:

No. Schneider’s official OSF troubleshooting for ATV61/71 starts with mains voltage verification, menu 1.2 monitoring, and DC bus measurement. Supply-side fluctuations and internal detection issues can also produce OSF. The surge board is one possible contributor, not the default cause.
No. The PN072146P1 is the surge absorption / filter board. The PN072139P904 (VX5A1300) is the SCR trigger / pre-charge board. They serve different functions in the input power path and are not interchangeable.
VX4A1110 is the commonly referenced spare-part designation for the PN072146P1 surge absorption board in ATV61/71 drives
Contact sales
E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069
Our products
We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.
Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.
Please contact us and we will serve you as soon as possible.