PN072323P702 Fan Control / Brake Board
The Schneider PN072323P702 is the fan control board used in Altivar ATV61 and ATV71 drives. Its primary function is to drive and monitor the drive’s cooling fans, translating the main control board’s thermal management commands into fan power and speed control. When fan operation is abnormal, the drive may report OHF (Drive Overheat) or a fan-related fault, depending on the frame and firmware configuration.
Important Identity Boundary — Fan Board, Not Brake Board: PN072323P702 is frequently listed alongside VZ3F111 and described as a “brake unit control board” on some spare-part channels. However, the drive’s spare-parts documentation and field listings distinguish the two: PN072323P702 is the fan control board, while VZ3F1113 is the separate dynamic brake board used for ATV61/71 models that require a braking option. The brake board sits in the braking/regeneration path and is a different physical assembly. Buyers searching for a brake board should confirm whether their drive actually uses VZ3F1113, not PN072323P702.
Supplied as a tested replacement unit, this board is intended for cases where fan control has been isolated as the fault source after fan motor and airflow checks.
| Specification | Details |
|---|---|
| Part Number | PN072323P702 |
| Product Type | Fan Control Board |
| Compatible Drives | Altivar ATV61 / ATV71 |
| Function | Cooling fan power supply and speed/on-off control |
| Related/Frequently Confused Part | VZ3F1113 — separate dynamic brake board(not this board) |
| Associated Drive Faults (Fan Side) | OHF — Drive overheat; fan-related faults |
| Associated Drive Faults (Brake Side, Reference Only) | OBF — Overbraking; bLF — Brake control fault |
| Condition | Tested replacement unit |

The board becomes the primary suspect on the fan side under these conditions, after external causes have been excluded:
Critical caution — OHF is not automatically a board fault: Before replacing this fan control board, confirm that the heatsink fins and airflow path are not clogged with dust or debris, and that the fan motor spins freely without bearing noise. In field practice, blocked airflow and a mechanically seized fan are at least as common as a failed control board when OHF appears。Schneider’s OHF guidance for ATV61/71 also specifies checking fan operation and top-of-drive blockage as the first steps.
Brake-side note: If the drive is reporting OBF or bLF, the relevant hardware is the brake board VZ3F1113 or the braking resistor/braking unit configuration, not PN072323P702. OBF is triggered when DC bus voltage reaches the braking threshold during operation, and the primary causes are deceleration time too short, high-inertia load, or missing/undersized braking resistor. Do not order a fan control board to resolve a brake-path fault.

Before ordering, confirm the following:
It is a fan control board. Some listings associate it with VZ3F111 and describe it as a brake unit control board, but the spare-parts documentation distinguishes PN072323P702(fan control) from VZ3F1113(dynamic brake board. The two are separate assemblies for different functions.
No. OHF is triggered when the drive thermal state reaches 118%。Blocked heatsink fins, a mechanically seized fan, or a fan motor failure can all produce OHF with a functional control board. Check airflow and fan freedom first.
No. OBF is a braking/overvoltage fault, not a fan fault. The relevant hardware is the brake board VZ3F1113 or the braking resistor/braking unit configuration. Check deceleration time and braking resistor sizing before replacing hardware.
Contact sales
E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069
Our products
We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.
Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.
Please contact us and we will serve you as soon as possible.