PN072135P903 Fan Control Board
The Schneider PN072135P903 is the dedicated fan control board for high-power Altivar ATV61 and ATV71 drives, covering models typically above 110 kW. It carries the spare-part designation VX5A1400. In the ATV61/71 platform, large-frame drives use a separate fan control card rather than an integrated cooling circuit; this board drives and regulates the heatsink cooling fan, translating the drive’s thermal management commands into fan speed and on/off control.
The board supports PWM fine speed regulation and is compatible with multiple fan types (including dual-speed / triple-speed variants). It communicates with the main control board and includes self-diagnostic capability for overvoltage, short-circuit, and open-circuit conditions on the fan supply path. Supplied as a tested replacement unit, it is intended for cases where the fan control board is confirmed faulty, or where fan operation is abnormal despite a serviceable fan and clear airflow path.
| Specification | Details |
|---|---|
| Part Number | PN072135P903 |
| Spare-Part Designation | VX5A1400 |
| Product Type | Fan Control Board (dedicated, high-power) |
| Compatible Drives | Schneider Altivar ATV61 / ATV71 (high-power models, typically > 110 kW) |
| Function | Heatsink fan speed regulation and on/off control |
| Fan Speed Control | PWM regulation; compatible with dual-speed / triple-speed fans |
| Self-Diagnostics | Overvoltage, short-circuit, open-circuit on fan path |
| Associated Drive Fault | OHF — Drive overheat (thermal state ≥ 118%) |
| Operating Temperature | Typically −25°C to +70°C (industrial environment) |
| Condition | Tested replacement unit |
Important Diagnostic Boundary: The PN072135P903 is the fan control board, not the fan assembly itself. When the drive trips on OHF, the correct diagnostic sequence is to first confirm whether the fan is physically running, whether the impeller or airflow path is blocked, and whether the thermal sensor signal is stable — before concluding the board is defective. Schneider’s official OHF troubleshooting for ATV61/71 specifies checking fan operation, top-of-drive blockage, and thermal state signal stability in menu 1.2 as the first steps.

The fan control board becomes the primary suspect under these conditions:
Critical caution: Before replacing the board, confirm the fan motor itself is serviceable (free rotation, no bearing noise, no physical obstruction) and that the heatsink fins and airflow path are not clogged. A blocked or worn fan will produce OHF even with a perfectly functional PN072135P903. Also verify that the thermal sensor signal is not jumping erratically in menu 1.2 — an unstable sensor reading can mimic a cooling fault.
Before ordering, confirm the following:

No. It is the fan control board only. The heatsink fan assembly is a separate component. Confirm whether the fan motor or the control board is faulty before ordering.
No. OHF is triggered when the drive’s thermal state reaches 118%. A blocked fan impeller, clogged heatsink fins, an unstable thermal sensor, or high ambient temperature can all produce OHF with a functional PN072135P903. Check the fan’s physical operation, airflow path, and thermal signal stability in menu 1.2 first.
VX5A1400 is the commonly used spare-part designation for the PN072135P903 fan control board in ATV61/71 high-power drives.
Contact sales
E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069
Our products
We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.
Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.
Please contact us and we will serve you as soon as possible.