A5E01206075 Capacitor/Power Board
The Siemens A5E01206075 is a DC-link capacitor and power control board used in SINAMICS G120 drive systems with PM240 / PM340 power modules. It carries the repair-part designation PM240-CBO2-400V/90KW FSF+ R1 COATED, indicating a 400 V class, coated power-stage board for the FSF frame size. Its function is to store and smooth energy on the DC bus, providing the stable intermediate circuit voltage required by the IGBT inverter stage.
Unlike Control Units or I/O boards, this is a power-stage component — its condition directly affects whether the drive can enable its output and pass internal hardware checks. Supplied as a tested replacement unit, it is intended for maintenance cases where capacitor degradation or power-module fault monitoring has been isolated to this board.
| Specification | Details |
|---|---|
| Part Number | A5E01206075 |
| Product Type | Capacitor / Power Control Board (DC-link) |
| Compatible Platform | SINAMICS G120, PM240 / PM340 power modules |
| Repair-Part Designation | PM240-CBO2-400V/90KW FSF+ R1 COATED |
| Voltage Class | 400 V AC, three-phase |
| Associated Fault Code | F30022 — Power module: VCE monitoring |
| Approx. Dimensions | 55 × 36 × 15 cm (repair-part packaging) |
| Related Part Numbers | A5E00496080, A5E01206074, A5E00496081 (verify equivalence against original label) |
| Condition | Tested replacement unit |
Important Diagnostic Distinction: F30022 is defined as “Power unit: Monitoring U_ce” — the drive has detected an abnormal collector-emitter voltage on the power semiconductors. While a degraded DC-link capacitor board can contribute to unstable bus conditions that trigger this fault, F30022 can also originate from IGBT failure, a missing gate-drive supply, an interrupted fiber-optic cable, or a short-circuit at the power unit output. Replacing the capacitor board is appropriate when capacitor degradation is confirmed or strongly suspected; it is not a guaranteed fix for every F30022 occurrence.

The board becomes the primary suspect under these conditions:
Before ordering, confirm the following:

It is a capacitor / power control board within the PM240/PM340 power module. It is not the Control Unit (CU) and not the IGBT module itself.
No. F30022 is a VCE monitoring fault in the power module. Capacitor degradation can contribute, but IGBT failure, gate-drive supply issues, and output short-circuits can also trigger it. Confirm capacitor condition and rule out simpler causes before replacing the board.
They appear as related power-board numbers in the same G120 PM240/PM340 family. Equivalence should be verified against the power module MLFB and the original board label before ordering.
Contact sales
E-mail: 1225353621a@gmail.com
Mobile:+86 15903995069
Whatsapp:+86 15903995069
WeChat:+8615903995069
Our products
We are an international supplier of industrial automation spare parts, providing tens of thousands of industrial automation products for users.
Even if the product you are looking for is not on our website, we may have the spare parts you are looking for.
Please contact us and we will serve you as soon as possible.